Buy ASTM E PRACTICE FOR ULTRASONIC EXAMINATION OF THE WELD ZONE OF WELDED PIPE AND TUBING from SAI. Status: Alert Withdrawn. Norwegian title: Standard Practice for Ultrasonic Testing of the Weld Zone of Welded Pipe and Tubing. English title: Standard Practice. Purchase your copy of ASTM E – 15 as a PDF download or hard copy directly from the official BSI Shop. All BSI British Standards available.

Author: Tadal Vugami
Country: Belgium
Language: English (Spanish)
Genre: Spiritual
Published (Last): 5 April 2017
Pages: 382
PDF File Size: 19.35 Mb
ePub File Size: 8.92 Mb
ISBN: 232-4-95218-251-4
Downloads: 54381
Price: Free* [*Free Regsitration Required]
Uploader: Zologor

The SI equivalents are in parentheses and may be approximate. This ensures that you are always up-to-date and saves you both time and money. Active view current version of standard. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.

Read more about subscriptions. The benefits of a subscription: If you need to be able to add standards to the monitoring service, you must register as a user with your own username and password. Webprint Printed and bound. Subscription – always available and updated A web subscription provides an easy and secure access to standards, and you are guaranteed astk always have the latest edition.

Monitoring Standards monitoring is a free service designed for you who wish to be alerted of changes to or new editions of the standards required in your work. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

ASTM E273:10

Note 1—When contact or unfocused immersion search units are used, precautions should be exercised when examining pipes or tubes near the lower specified limits. When properly focused immersion search units are employed, this practice may also be applied to material of smaller diameter and thinner wall. When properly focused immersion search units are employed, this practice may also be applied to material of smaller diameter and thinner wall.

  DOA SELEPAS WUDUK PDF

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Link to Active This link will e2273 route to the current Active version of the standard.

ASTM E – 15 Standard Practice for Ultrasonic Testing of the Weld Zone of Welded Pipe and Tubing

The configuration of the weld must be such that interfering signals are not generated by reflections from it. This service is not available if you are a URL user where you do not log in with an email address. And when properly focused immersion search units are employed, this practice may also be applied to material of smaller diameter and thinner wall.

This abstract is a brief summary of the referenced standard. When contact or unfocused immersion search units are employed, this practice is intended for tubular products having specified outside diameters and wall thicknesses.

When contact or unfocused immersion search units are used, precautions should be exercised when examining pipes or tubes near the lower specified limits. You need to log in before adding standards to the monitoring service. Certain combinations of search unit size, frequency, thin-wall thicknesses, and small diameters could cause generation of unwanted sound waves that may produce erroneous examination results.

Referenced Documents purchase separately The ast, listed below are referenced within the subject standard but are not provided as part of the standard. The moment new editions of the standards you monitor are released, changes are made, or appendixes are ashm, you will be alerted by email.

Standard Practice for Ultrasonic Testing of the Weld Zone of Welded Pipe and Tubing

This practice describes the general ultrasonic examination procedures for the detection of discontinuities in the weld and adjacent heat affected zones of welded pipe and tubing by scanning with relative motion between the search unit and pipe or tube.

  EISENHEIM THE ILLUSIONIST BY STEVEN MILLHAUSER PDF

A pulsed ultrasonic angle beam shall be propagated in the wall of the pipe or tube by either the surface contact or immersion method. Start Webshop Product catalog Product presentation. Certain combinations of search unit size, frequency, thin—wall thicknesses, and small diameters could cause generation of unwanted sound waves that may produce erroneous examination results. The configuration of the weld must be such that interfering signals are not generated by reflections from it.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Link to Active This link will always route to the current Active version of the standard. This practice does not establish acceptance criteria for this procedure.

It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. The weld line shall then be examined from both sides to ensure detection of imperfections with a shape or orientation that produces a preferential direction of reflection.

Historical Version s – view previous versions of standard. Standards monitoring is a free service designed for you who wish to be alerted of changes to or new editions of the standards required in your work. The SI equivalents are in parentheses and may be approximate. Treatment of the inner surface and outer surface weld beads such as trimming “scarfing” or rolling is often required to remove protuberances that could result in spurious reflections. A web subscription provides an easy and secure access to standards, and you are guaranteed to always have the latest edition.